Pipeline Centrifugal Pumps & CDL Multistage PumpsLarge CDL(F) Pumps: 65 to 150 m³/h at Up to 161 m
The CDL(F) 65, 85, 120 and 150 move 65 to 150 m³/h at heads up to 161 m with motors up to 75 kW. Sizes, ports and the -1/-2 builds.

Model: CDL(F) 2 and CDL(F) 4
The CDL(F) 2 and 4 deliver 2 and 4 m³/h at heads up to 198 m and 178 m. Where these small multistage pumps fit and how to pick the stage count.
| Flow Rate | 2 and 4 m³/h |
|---|---|
| Head | 15 to 198 m |
| Power | 0.55 to 4 kW |
| Inlet / Outlet Diameter | DN25 and DN32 |
| Material | Stainless steel wetted parts |
Not sure this pump fits your duty? Try the pump selector
Some duties need very little water at a lot of pressure. The two smallest CDL(F) sizes cover them with small motors.
| Model | Flow (m³/h) | Head (m) | Motor (kW) |
|---|---|---|---|
| CDL(F) 2-20 | 2 | 15 | 0.55 |
| CDL(F) 2-100 | 2 | 74 | 1.1 |
| CDL(F) 2-260 | 2 | 198 | 3 |
| CDL(F) 4-20 | 4 | 15 | 0.55 |
| CDL(F) 4-100 | 4 | 81 | 2.2 |
| CDL(F) 4-220 | 4 | 178 | 4 |
Head rises by roughly 7 to 8 m per stage in these sizes, so it is easy to pick a stage count close to your duty.
All 45 builds of the two sizes are in the CDL(F) selection table.
Pipeline Centrifugal Pumps & CDL Multistage PumpsThe CDL(F) 65, 85, 120 and 150 move 65 to 150 m³/h at heads up to 161 m with motors up to 75 kW. Sizes, ports and the -1/-2 builds.
Pipeline Centrifugal Pumps & CDL Multistage PumpsThe hot water CDL(F) handles liquids from -15 to 140 °C for boiler feed and condensate. Pressure, NPSH and what to check on hot duties.
Pipeline Centrifugal Pumps & CDL Multistage PumpsCleaning systems, high-pressure washing and car washes need small flows at high head. How CDL(F) pumps fit, with an example at 4 m³/h and 100 m.