Case: CDL 85-30-2 Multistage Pump, 18.5 kW, for Inner Mongolia

This order came in 2025: one large vertical multistage pump for a site in Inner Mongolia. Factories write the model in two ways, CDL85-3-2 or CDL 85-30-2. Both mean the same pump.
| Item | Order detail |
|---|---|
| Model | CDL 85-30-2 |
| Rated point | 85 m³/h at 52 m |
| Motor | 18.5 kW |
| Ports | DN100 |
| Weight | About 260 kg |
| Ready to ship | About three days |
What the -2 means
In the big CDL sizes each full stage adds a lot of head, so the range has in-between builds. The 85-20 gives 41 m and the full 85-30 gives 64 m. The 85-30-2 has trimmed stages and lands at 52 m with a smaller 18.5 kW motor instead of 22 kW. If 52 m covers the duty, that saves power on every hour the pump runs.
Planning for a 260 kg pump
- Lifting gear on site, as it cannot be moved by hand
- A solid, level foundation with the base bolted down
- Pipe supports on both sides so the DN100 pipework does not hang on the pump
- A starting method agreed with your electrician for the 18.5 kW motor
All CDL 85 builds are in the CDL(F) selection table.
Products in This Series
Pipeline Centrifugal Pumps & CDL Multistage PumpsBoiler Feed and Condensate Return with the Hot Water CDL(F)
The hot water CDL(F) handles liquids from -15 to 140 °C for boiler feed and condensate. Pressure, NPSH and what to check on hot duties.
Pipeline Centrifugal Pumps & CDL Multistage PumpsMultistage Pumps for Washing, High-Pressure Cleaning and Car Wash
Cleaning systems, high-pressure washing and car washes need small flows at high head. How CDL(F) pumps fit, with an example at 4 m³/h and 100 m.
Pipeline Centrifugal Pumps & CDL Multistage PumpsCDL(F) Pumps for Sprinkler and Drip Irrigation
Sprinkler and drip systems need pressure as well as flow. How to size a CDL(F) multistage irrigation pump, with an example at 12 m³/h and 50 m.
Need a pump for your application?
Our engineers respond to technical inquiries within 24 hours.
Get a Quote