200QW250-18-22 Sewage Pump: Factory Test Results
200QW250-18-22 submersible sewage pump: 250 m³/h at 18 m, 22 kW, DN200. Factory test results: 19.19 m at 250 m³/h and 68.6% pump efficiency.

Model: WQ/QW
65mm WQ/QW submersible sewage pumps, 25-37m³/h, with GAK-65 auto-coupling. Standard and grinder versions for food-plant wastewater.
| Flow Rate | 25-37m³/h |
|---|---|
| Head | 13-15m |
| Power | 2.2-3kW |
| Inlet / Outlet Diameter | DN65 |
| Material | Cast Iron, SS304, SS316L |
Not sure this pump fits your duty? Try the pump selector
This is roughly where the lineup stops feeling like a utility pump and starts feeling like real infrastructure — permanent installations, food-plant wastewater, small municipal lift duty.
| Model | Flow (m³/h) | Head (m) | Power (kW) | Type |
| WQ-65-25-15 | 25 | 15 | 2.2 | Standard |
| QW-65-37-13 | 37 | 13 | 3 | Higher flow |
| WQ-G-65-25-13 | 25 | 13 | 2.2 | Grinder version |
The grinder variant shares the same hydraulics as the standard WQ-65 — same flow, same head — with a cutting assembly added ahead of the impeller for sites handling animal fibre or skin fragments, seafood or slaughter-house wastewater being the common case. Whichever you pick, this is also the point in the range where calculating your actual pipe-friction losses starts to matter more than trusting the catalogue number directly.

200QW250-18-22 submersible sewage pump: 250 m³/h at 18 m, 22 kW, DN200. Factory test results: 19.19 m at 250 m³/h and 68.6% pump efficiency.

200QW300-15-22 submersible sewage pump: 300 m³/h at 15 m, 22 kW 4-pole, DN200 outlet. Installation dimensions, flange data and drawing download.

150QW180-15-15 submersible sewage pump: 180 m³/h at 15 m, 15 kW 4-pole, 1450 r/min, DN150. Performance curve explained and installation dimensions.