ZW40-10-20 Self-Priming Sewage Pump with DN40 Suction
ZW40-10-20: 10 m³/h at 20 m, 2.2 kW. Why the suction is DN40 and the discharge DN32, and how to plan the pipework.

Model: ZW32-5-20
ZW32-5-20: 5 m³/h at 20 m, 2.2 kW, DN32. What each part of a ZW model name means, including the P and B suffixes.
| Flow Rate | 5m³/h |
|---|---|
| Head | 20m |
| Power | 2.2kW |
| Inlet / Outlet Diameter | 32 / 32mm |
| Material | Cast iron (standard); stainless steel on request |
Not sure this pump fits your duty? Try the pump selector
ZW32-5-20 gives 5 m³/h at 20 m head on 2.2 kW. It is the lowest-flow model in the range, for duties where the liquid has to be lifted a fair way but the volume is small.
Our catalogue writes the model two ways, ZW32-5-20 and 32ZW5-20. Both mean the same pump:
So 32ZW5-20PB would be this pump in stainless steel with an explosion-proof motor. When you send an enquiry, the full name is enough for us to know exactly what you need.
| Item | ZW32-5-20 |
|---|---|
| Flow | 5 m³/h |
| Head | 20 m |
| Motor power | 2.2 kW |
| Speed | 2900 r/min |
| Efficiency | 45 % |
| NPSHr | 2.5 m |
| Self-priming height | 5.5 m |
| Self-priming time | 3 min per 5 m |
| Suction / discharge | DN32 / DN32 |
| Weight | 100 kg |
The pump, coupling and motor are mounted on a common base. L is the overall length; L1 to L4 are base lengths; a and f locate the outlet; B1 and B2 are the base widths; H is the shaft centre height; h1 and h2 are the heights of the suction and discharge flanges; h3 is the base thickness.
| L | L1 | L2 | L3 | L4 | a | f | B1 | B2 | H | h1 | h2 | h3 | Base bolts | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZW32-5-20 | 850 | 680 | 115 | 450 | 240 | 255 | 510 | 310 | 370 | 228 | 410 | 625 | 24 | 4ר18 |
| Flange | DN | Outer dia. D | Bolt circle | Raised face | Thickness b | Face height f | Bolts n×d |
|---|---|---|---|---|---|---|---|
| Suction | 32 | 120 | 90 | 70 | 14 | 2 | 4ר14 |
| Discharge | 32 | 120 | 90 | 70 | 14 | 2 | 4ר14 |

ZW40-10-20: 10 m³/h at 20 m, 2.2 kW. Why the suction is DN40 and the discharge DN32, and how to plan the pipework.

ZW32-9-30 lifts 9 m³/h to 30 m on 3 kW with DN32 flanges. A worked example of checking suction lift before you buy.

ZW32-10-20: 10 m³/h at 20 m, 2.2 kW, DN32 flanges. How it compares with the other 2.2 kW ZW pumps on the same base.