ZW32-9-30 Self-Priming Sewage Pump, 30 m Head on 3 kW
ZW32-9-30 lifts 9 m³/h to 30 m on 3 kW with DN32 flanges. A worked example of checking suction lift before you buy.

Model: ZW40-10-20
ZW40-10-20: 10 m³/h at 20 m, 2.2 kW. Why the suction is DN40 and the discharge DN32, and how to plan the pipework.
| Flow Rate | 10m³/h |
|---|---|
| Head | 20m |
| Power | 2.2kW |
| Inlet / Outlet Diameter | 40 / 32mm |
| Material | Cast iron (standard); stainless steel on request |
Not sure this pump fits your duty? Try the pump selector
ZW40-10-20 delivers 10 m³/h at 20 m on 2.2 kW. Its suction flange is DN40 and its discharge flange DN32.
A self-priming pump is most sensitive on the suction side. A larger inlet keeps the velocity in the suction pipe low, which helps priming and lets larger solids reach the impeller. On the discharge side the liquid is under pressure, so a smaller port is fine.
Flange dimensions for both ports are in the table below, so you can order matching flanges before the pump arrives.
Inlet and outlet sizes can differ, as they do on this model, and both can be made to order. Give us your pipe sizes and we will match them.
| Item | ZW40-10-20 |
|---|---|
| Flow | 10 m³/h |
| Head | 20 m |
| Motor power | 2.2 kW |
| Speed | 2900 r/min |
| Efficiency | 45 % |
| NPSHr | 2.5 m |
| Self-priming height | 5.5 m |
| Self-priming time | 3 min per 5 m |
| Suction / discharge | DN40 / DN32 |
| Weight | 100 kg |
The pump, coupling and motor are mounted on a common base. L is the overall length; L1 to L4 are base lengths; a and f locate the outlet; B1 and B2 are the base widths; H is the shaft centre height; h1 and h2 are the heights of the suction and discharge flanges; h3 is the base thickness.
| L | L1 | L2 | L3 | L4 | a | f | B1 | B2 | H | h1 | h2 | h3 | Base bolts | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZW40-10-20 | 850 | 680 | 115 | 450 | 240 | 255 | 510 | 310 | 370 | 228 | 410 | 625 | 24 | 4ר18 |
| Flange | DN | Outer dia. D | Bolt circle | Raised face | Thickness b | Face height f | Bolts n×d |
|---|---|---|---|---|---|---|---|
| Suction | 40 | 130 | 100 | 80 | 14 | 2 | 4ר14 |
| Discharge | 32 | 120 | 90 | 70 | 14 | 2 | 4ר14 |