WILDEN P2 & P200 1″ Polypropylene & PVDF AODD Pumps

Model: WILDEN P2 (Pro-Flo, clamped) / P200 (Pro-Flo, bolted)

Genuine WILDEN P2 and P200 1″ plastic diaphragm pumps in polypropylene or PVDF, ANSI flanged: 37 to 57 gpm (140 to 216 L/min), 161 builds.

Specifications
Flow RateP2: up to 37 gpm / 140 L/min. P200: up to 57 gpm / 216 L/min (12.9 m³/h)
HeadMax air pressure 120 psi / 8.3 bar
PowerCompressed air, max 8.3 bar (120 psi)
Inlet / Outlet Diameter1" inlet / 1" outlet, ANSI flanged
MaterialPolypropylene or PVDF wetted path, polypropylene air side; PTFE, Santoprene, FKM, Buna-N, EPDM, Hytrel, Neoprene or Bunalast diaphragms

Product Overview

The 1 inch plastic Wilden pumps show a trade-off that is easy to miss if you only look at maximum flow. The bolted P200 moves more liquid. The clamped P2 lifts much further.

P2 (02-11915 PP / 02-10470 PVDF)P200 (02-12485 PP / 02-10718 PVDF)
Max flow37 gpm (140 L/min)57 gpm (216 L/min)
Dry suction lift28 ft (8.5 m)11.4 ft (3.5 m)
Max solids0.13 in (3.3 mm)0.18 in (4.6 mm)
Max air pressure120 psi (8.3 bar)120 psi (8.3 bar)
Weight, PP / PVDF17.1 / 22.2 lb (7.8 / 10.1 kg)22 / 32 lb (10 / 14.5 kg)
Builds, PP / PVDF43 / 2747 / 44

Which matters for your duty

  • Pumping out of a pit, sump or tanker from above: the P2’s 28 ft (8.5 m) dry lift, the highest of any Wilden page we have checked, gives real margin
  • Flooded suction from a tank, where flow is the priority: the P200 delivers about half as much again
  • Liquids with small particles: the P200 passes slightly larger solids

Both have ANSI flanged ports on all but two builds, which makes them straightforward to fit into plastic process pipework. PTFE diaphragms are the most common choice on both, with Santoprene second.

Suction lift falls with heavier or hotter liquids, so treat the dry figures as best case and tell us the real conditions when you ask for a recommendation.

Example builds

Part No.Build codeElastomerMaterial
02-11768P2/PKPPP/TEU/TF/PTV/0400PTFEPolypropylene
02-11915P2/PKPPP/WFS/NE/PBN/0400SantoprenePolypropylene
02-6274P2/PKPPP/VTS/TF/PTV/0400FKMPolypropylene
02-12822P2/PKPPP/EPS/EP/PBN/0400EPDMPolypropylene
02-10459P2/PKPPP/BNS/BN/KBN/0400Buna-NPolypropylene
02-10275P2/PKPPP/FSS/FS/PBN/0400HytrelPolypropylene
02-6240P2/PKPPP/NES/NE/PBN/0400NeoprenePolypropylene
02-12533P2/PKPPP/GEU/TF/PTV/0400BunalastPolypropylene

All 161 plastic builds are listed in our part number lookup. Polypropylene builds: P2 | P200. PVDF builds: P2 | P200.

Typical Applications

  • acid and caustic unloading
  • chemical transfer from pits and sumps
  • plating lines
  • wastewater chemical dosing

Related Products

WILDEN P1500 3″ Polypropylene & PVDF AODD Pump & PS1500 — Genuine Wilden AODD Diaphragm Pumps & Spare Parts by Haquan
Genuine Wilden AODD Diaphragm Pumps & Spare Parts

WILDEN P1500 3″ Polypropylene & PVDF AODD Pump & PS1500

Genuine WILDEN P1500 and PS1500, the largest plastic Wilden diaphragm pumps: 3″ ANSI flanged, polypropylene or PVDF, up to 271 gpm (1026 L/min), 47 builds.

P1500: up to 195 gpm / 738 L/min. PS1500: up to 271 gpm / 1026 L/min (61.6 m³/h)
Flow Rate (m³/h)
P1500: max air 100 psi / 6.9 bar. PS1500: max air 125 psi / 8.6 bar
Head (m)
Compressed air; max 6.9 bar (100 psi) for P1500, 8.6 bar (125 psi) for PS1500
Power (kW)