200QW250-18-22 Sewage Pump: Factory Test Results
200QW250-18-22 submersible sewage pump: 250 m³/h at 18 m, 22 kW, DN200. Factory test results: 19.19 m at 250 m³/h and 68.6% pump efficiency.

Model: WQ/QW
250mm WQ submersible sewage pumps, all rated 600m³/h across five head/power combinations, for large municipal and industrial sump stations.
| Flow Rate | 600m³/h |
|---|---|
| Head | 9-25m |
| Power | 30-75kW |
| Inlet / Outlet Diameter | DN250 |
| Material | Cast Iron, SS304, SS316L |
Not sure this pump fits your duty? Try the pump selector
Every model at this size holds the same 600 m³/h; what changes across the five variants is purely head and the motor needed to reach it.
| Model | Flow (m³/h) | Head (m) | Power (kW) |
| WQ-250-600-9 | 600 | 9 | 30 |
| WQ-250-600-12 | 600 | 12 | 37 |
| WQ-250-600-15 | 600 | 15 | 45 |
| WQ-250-600-20 | 600 | 20 | 55 |
| WQ-250-600-25 | 600 | 25 | 75 |
Picking between these five is really a pipeline-head exercise: calculate your total system head (pipe friction, elbows, valves) and match it to the closest column rather than rounding up “to be safe,” which just adds cost and an oversized motor cycling below its rated point. From the 45kW model up, a soft-starter in the control cabinet stops being optional in any practical sense; direct-on-line starting at this power creates a surge that stresses both motor and local grid more than most sites are built to absorb.

200QW250-18-22 submersible sewage pump: 250 m³/h at 18 m, 22 kW, DN200. Factory test results: 19.19 m at 250 m³/h and 68.6% pump efficiency.

200QW300-15-22 submersible sewage pump: 300 m³/h at 15 m, 22 kW 4-pole, DN200 outlet. Installation dimensions, flange data and drawing download.

150QW180-15-15 submersible sewage pump: 180 m³/h at 15 m, 15 kW 4-pole, 1450 r/min, DN150. Performance curve explained and installation dimensions.