ZW80-40-25 Self-Priming Pump for Sewage Lift Stations
ZW80-40-25: 40 m³/h at 25 m on 7.5 kW, 1450 r/min, DN80/DN65. Why dry-installed self-priming pumps suit small lift stations.

Model: ZW80-25-40
ZW80-25-40: 25 m³/h at 40 m, 7.5 kW, DN80/DN65. Using the head for a long pipeline rather than a high lift.
| Flow Rate | 25m³/h |
|---|---|
| Head | 40m |
| Power | 7.5kW |
| Inlet / Outlet Diameter | 80 / 65mm |
| Material | Cast iron (standard); stainless steel on request |
Not sure this pump fits your duty? Try the pump selector
Head is not only height. On a long pipeline most of it goes into pipe friction. ZW80-25-40, with 25 m³/h at 40 m on 7.5 kW, is often chosen for exactly that: sending wastewater a long way to a treatment tank.
Suppose the outlet is only 8 m above the pump but the line is several hundred metres long. In a DN65 pipe at 25 m³/h, friction can use up a large part of the remaining head, depending on the pipe and fittings. A larger discharge pipe cuts that loss sharply. Put the real lengths into our head calculator before choosing between this model and a smaller one.
The same hydraulics with a DN65 suction are available as ZW65-25-40.
On a long line you may want a larger discharge than DN65. The outlet, and the inlet, can be made to the size you specify.
| Item | ZW80-25-40 |
|---|---|
| Flow | 25 m³/h |
| Head | 40 m |
| Motor power | 7.5 kW |
| Speed | 2900 r/min |
| Efficiency | 50 % |
| NPSHr | 3.0 m |
| Self-priming height | 5.5 m |
| Self-priming time | 2 min per 5 m |
| Suction / discharge | DN80 / DN65 |
| Weight | 200 kg |
The pump, coupling and motor are mounted on a common base. L is the overall length; L1 to L4 are base lengths; a and f locate the outlet; B1 and B2 are the base widths; H is the shaft centre height; h1 and h2 are the heights of the suction and discharge flanges; h3 is the base thickness.
| L | L1 | L2 | L3 | L4 | a | f | B1 | B2 | H | h1 | h2 | h3 | Base bolts | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZW80-25-40 | 1230 | 850 | 135 | 580 | 340 | 350 | 700 | 370 | 520 | 270 | 480 | 720 | 25 | 4ר18 |
| Flange | DN | Outer dia. D | Bolt circle | Raised face | Thickness b | Face height f | Bolts n×d |
|---|---|---|---|---|---|---|---|
| Suction | 80 | 190 | 150 | 125 | 15 | 2 | 4ר18 |
| Discharge | 65 | 160 | 130 | 110 | 14 | 2 | 4ר14 |

ZW80-40-25: 40 m³/h at 25 m on 7.5 kW, 1450 r/min, DN80/DN65. Why dry-installed self-priming pumps suit small lift stations.

ZW80-40-16: 40 m³/h at 16 m, 4 kW, 1450 r/min, DN80 inlet. A practical pump for muddy site water and foundation pits.

ZW65-65-25 is the largest DN65 ZW pump: 65 m³/h at 25 m, 11 kW. The DN65 line side by side.