Work out the total head your sewage pump needs, from the static height, pipe length, pipe size and fittings, with a system curve for your pipeline.

Your system

Vertical height from the lowest liquid level in the pit to the highest point of discharge.

Fittings (quantity)

Leave 0 when the pipe discharges freely into a tank, channel or manhole.

Recommended pump head (incl. 10% margin)

10.7 m

Calculated total dynamic head: 9.72 m at 40 m³/h

Static height
8 m
Pipe friction loss
1.03 m
Fittings and exit loss
0.69 m
Velocity in pipe
1.41 m/s
System curve(head required at each flow)
03.266.539.7913.1015304560Q (m³/h)H (m)40 m³/h · 9.72 m

The pump runs where its own curve crosses this line. Choose a pump whose curve passes through or just above the orange point.

Find pumps for 40 m³/h at 10.7 m with the pump selector.

Find a pump

How the pump head is calculated

The total dynamic head (TDH) the pump has to deliver is the sum of four parts:

  • Static height: the vertical distance from the lowest liquid level to the highest point of the discharge pipe.
  • Pipe friction loss: from the Darcy–Weisbach equation hf = f · (L/D) · v² / 2g, with the friction factor f from the Swamee–Jain equation for your pipe material.
  • Fitting losses: hm = ΣK · v² / 2g, using standard K values for elbows, valves and tees, plus 1.0 for the exit loss at a free outlet.
  • Outlet pressure: any pressure required at the end of the pipe, converted to metres (1 bar ≈ 10.2 m of water).

The calculation assumes water at about 20 °C, which is also a good approximation for dilute sewage. For thick sludge or viscous liquids, ask our engineers for a detailed calculation.

The system curve

The chart shows the head your pipeline needs at every flow. Static height and outlet pressure stay constant, while friction and fitting losses grow with the square of the flow. The pump will run at the point where its own curve crosses this line.

Once you have the head, the pump selector shows which Haquan pumps suit your duty point.