HQHaquanPump & Valve
QJ Deep Well Submersible Pump Selection Table: 100QJ to 200QJ — Deep Well Pumps
Deep Well Pumps

QJ Deep Well Submersible Pump Selection Table: 100QJ to 200QJ

Model: 100QJ, 150QJ, 175QJ, 200QJ deep well submersible pumps

Full QJ deep well submersible pump table, 100QJ to 200QJ: flow 2 to 50 m³/h, head up to 450 m, 0.75 to 45 kW, with outlet, current and cable for every model.

Specifications
Flow Rate2 to 50 m³/h
Head6 to 450 m
Power0.75 to 45 kW, three-phase submersible motor
Inlet / Outlet DiameterOutlet 40 to 80 mm; for wells from 100 mm (4 inch) to 200 mm (8 inch)
MaterialStainless steel and cast iron versions
Inquire About This Product

Not sure this pump fits your duty? Try the pump selector

Product Overview

This table covers our QJ deep well submersible pumps from the 100QJ, which fits a 100 mm (4 inch) well, up to the 200QJ for 200 mm (8 inch) wells. Flow runs from 2 to 50 m³/h and head up to 450 m. Start with the summary to find the right size for your well, then pick the exact model in the full list below.

How to read a QJ model number

Take 150QJ20-65/10 as an example. 150 is the smallest well diameter the pump fits, in mm. QJ means deep well submersible pump. 20 is the rated flow in m³/h, 65 the rated head in metres, and 10 the number of stages (impellers). Head rises with the number of stages, which is why one flow size comes in many heads.

Summary by well size

SeriesMinimum well diameterPump outside diameterFlow (m³/h)Head (m)Motor (kW)Outlet
100QJ100 mm95 mm2 to 1515 to 2300.75 to 7.540, 50 mm
150QJ150 mm142 mm5 to 506 to 3003 to 18.550, 65, 80 mm
175QJ175 mm169 mm10 to 5024 to 2473 to 2550, 65, 80 mm
200QJ200 mm182 mm20 to 5013 to 4504 to 4550, 65, 80 mm

Choosing a size

  • Measure the inside diameter of the well. The series number must not be larger than it, and some clearance around the pump helps cooling and installation
  • Work out the head: the depth from the ground to the lowest (dynamic) water level, plus the height and pipe losses above ground
  • Pick the flow size closest to what you need, then the model with the head just above your figure
  • Check the motor current and cable size against your power supply and cable length

Motor type

The 100QJ series uses a sealed oil-filled motor. It must not be filled with water. Water-filled motors are filled with clean water before installation and drained before storage in freezing weather. Check the nameplate and the manual for the motor type before installing.

Full model list

All motors are three-phase. Current is the rated current; cable is the recommended submersible cable for the motor.

100QJ series (pump diameter 95 mm)

ModelFlow (m³/h)Head (m)StagesMotor (kW)Current (A)Outlet (mm)Cable (mm²)
100QJ2-50/10250100.752403×1.5+1×1
100QJ2-70/14270141.13.1403×1.5+1×1
100QJ2-80/16280161.13.1403×1.5+1×1
100QJ2-100/202100201.53.8403×1.5+1×1
100QJ2-110/222110221.53.8403×1.5+1×1
100QJ2-140/282140281.53.8403×1.5+1×1
100QJ2-150/302150302.25.6403×2.5+1×1.5
100QJ2-160/322160322.25.6403×2.5+1×1.5
100QJ2-190/382190382.25.6403×2.5+1×1.5
100QJ2-200/4022004037.3403×4+1×2.5
100QJ3.2-40/63.24060.752403×1.5+1×1
100QJ3.2-54/83.25480.752403×1.5+1×1
100QJ3.2-68/103.268101.13.1403×1.5+1×1
100QJ3.2-72/113.272111.13.1403×1.5+1×1
100QJ3.2-99/153.299151.53.8403×1.5+1×1
100QJ3.2-108/163.2108162.25.6403×2.5+1×1.5
100QJ3.2-135/203.2135202.25.6403×2.5+1×1.5
100QJ3.2-144/213.21442137.3403×4+1×2.5
100QJ3.2-170/253.21702537.3403×4+1×2.5
100QJ3.2-230/343.223034410.26403×4+1×2.5
100QJ5-24/652460.752403×1.5+1×1
100QJ5-36/953691.13.1403×1.5+1×1
100QJ5-48/12548121.53.8403×1.5+1×1
100QJ5-64/16564162.25.6403×1.5+1×1
100QJ5-72/18572182.25.6403×1.5+1×1
100QJ5-88/225882237.3403×2.5+1×1.5
100QJ5-96/245962437.3403×2.5+1×1.5
100QJ5-108/2751082737.3403×4+1×2.5
100QJ5-128/32512832410.26403×4+1×2.5
100QJ5-164/415164415.513.74403×4+1×2.5
100QJ5-220/555220557.518.5403×6+1×4
100QJ8-15/381530.752503×1.5+1×1
100QJ8-20/482041.13.1503×1.5+1×1
100QJ8-30/683061.53.8503×1.5+1×1
100QJ8-40/884082.25.6503×1.5+1×1
100QJ8-50/108501037.3503×2.5+1×1.5
100QJ8-60/128601237.3503×2.5+1×1.5
100QJ8-70/148701437.3503×2.5+1×1.5
100QJ8-85/1788517410.26503×2.5+1×1.5
100QJ8-95/19895195.513.74503×4+1×2.5
100QJ8-100/208100205.513.74503×4+1×2.5
100QJ8-110/228110225.513.74503×4+1×2.5
100QJ8-135/278135277.518.5503×4+1×2.5
100QJ8-150/308150307.518.5503×4+1×2.5
100QJ10-48/101048102.25.6503×1.5+1×1
100QJ10-60/1310601337.3503×2.5+1×1.5
100QJ10-80/17108017410.26503×2.5+1×1.5
100QJ10-108/2210108225.513.74503×4+1×2.5
100QJ10-130/2710130277.518.5503×4+1×2.5
100QJ15-34/1015341037.3503×2.5+1×1.5
100QJ15-52/14155214410.26503×2.5+1×1.5
100QJ15-58/181558185.513.74503×4+1×2.5
100QJ15-82/241582247.518.5503×4+1×2.5

150QJ series (pump diameter 142 mm)

ModelFlow (m³/h)Head (m)StagesMotor (kW)Current (A)Outlet (mm)Cable (mm²)
150QJ5-85/125851237.9503×4
150QJ5-100/1451001437.9503×4
150QJ5-150/21515021410.26503×4
150QJ5-200/285200285.513.74503×6
150QJ5-250/355250357.518.5503×6
150QJ5-300/425300429.222.12503×10
150QJ10-50/71050737.9503×4
150QJ10-78/11107811410.26503×4
150QJ10-100/1410100145.513.74503×4
150QJ10-128/1810128187.518.5503×6
150QJ10-150/2110150217.518.5503×6
150QJ10-178/2510178259.222.12503×6
150QJ10-200/2810200281126.28503×10
150QJ10-250/3510250351330.87503×10
150QJ10-300/4210300421535.62503×16
150QJ20-26/42026437.9503×4
150QJ20-33/52033537.9503×4
150QJ20-39/620396410.26503×4
150QJ20-46/7204675.513.74503×4
150QJ20-52/8205285.513.74503×4
150QJ20-59/9205995.513.74503×4
150QJ20-65/102065107.518.5503×4
150QJ20-72/112072117.518.5503×4
150QJ20-78/122078127.518.5503×6
150QJ20-85/132085139.222.12503×6
150QJ20-91/142091149.222.12503×6
150QJ20-98/152098159.222.12503×6
150QJ20-104/1620104161126.28503×6
150QJ20-111/1720111171126.28503×6
150QJ20-117/1820117181330.87503×6
150QJ20-124/1920124191330.87503×6
150QJ20-130/2020130201330.87503×6
150QJ20-137/2120137211535.62503×6
150QJ20-143/2220143221535.62503×6
150QJ20-150/2320150231535.62503×6
150QJ20-156/2420156241535.62503×10
150QJ20-163/2520163251535.62503×10
150QJ25-24/32524337.9653×4
150QJ25-32/425324410.3653×4
150QJ25-40/5254055.513.7653×4
150QJ25-48/6254865.513.7653×4
150QJ25-56/7255677.518.5653×4
150QJ25-64/8256487.518.5653×4
150QJ25-72/9257299.222.1653×6
150QJ25-80/102580109.222.1653×6
150QJ25-88/112588111126.3653×6
150QJ25-96/122596121126.3653×6
150QJ25-104/1325104131330.9653×6
150QJ25-112/1425112141330.9653×6
150QJ25-120/1525120151535.6653×6
150QJ25-128/1625128161535.6653×6
150QJ25-136/17251361718.544653×10
150QJ25-144/18251441818.544653×10
150QJ25-152/19251521918.544653×10
150QJ32-18/33218337.9653×4
150QJ32-24/432244410.26653×4
150QJ32-30/5323055.513.74653×4
150QJ32-36/6323665.513.74653×4
150QJ32-42/7324277.518.5653×6
150QJ32-54/9325499.222.12653×6
150QJ32-66/113266111126.28653×6
150QJ32-72/123272121330.87653×6
150QJ32-84/143284141330.87653×6
150QJ32-90/153290151535.62653×6
150QJ32-96/163296161535.62653×6
150QJ32-108/18321081818.544653×10
150QJ50-6/1506137.9803×4
150QJ50-12/250122410.26803×4
150QJ50-18/3501835.513.74803×4
150QJ50-24/4502447.518.5803×6
150QJ50-30/5503059.222.12803×6
150QJ50-36/6503669.222.12803×6
150QJ50-42/7504271126.28803×6
150QJ50-48/8504881330.87803×6
150QJ50-54/9505491535.62803×6
150QJ50-60/1050601018.544803×6
150QJ50-66/1150661118.544803×6
150QJ50-72/1250721218.544803×10

175QJ series (pump diameter 169 mm)

ModelFlow (m³/h)Head (m)StagesMotor (kW)Current (A)Outlet (mm)Cable (mm²)
175QJ10-30/21030237.8503×4
175QJ10-45/310453410.1503×4
175QJ10-60/4106045.513.6503×4
175QJ10-90/6109067.518.4503×6
175QJ10-105/71010579.222.1503×6
175QJ10-135/91013591126.1503×6
175QJ20-26/22026237.8503×4
175QJ20-39/320393410.1503×4
175QJ20-52/4205245.513.6503×6
175QJ20-65/5206557.518.4503×6
175QJ20-78/6207867.518.4503×6
175QJ20-91/7209179.222.1503×6
175QJ20-104/82010481126.1503×6
175QJ20-117/92011791330.1503×6
175QJ20-130/1020130101330.1503×6
175QJ20-143/1120143111534.7503×6
175QJ20-156/1220156121534.7503×6
175QJ20-169/13201691318.542.6503×10
175QJ20-182/14201821418.542.6503×10
175QJ20-195/1520195152249.7503×16
175QJ20-208/1620208162249.7503×16
175QJ20-221/1720221172556.5503×16
175QJ20-234/1820234182556.5503×16
175QJ20-247/1920247192556.5503×16
175QJ32-24/232242410.1653×4
175QJ32-36/3323635.513.6653×4
175QJ32-48/4324847.518.4653×4
175QJ32-60/5326059.222.1653×6
175QJ32-72/6327261126.1653×6
175QJ32-84/7328471330.1653×6
175QJ32-96/8329681534.7653×6
175QJ32-120/10321201018.542.6653×10
175QJ32-144/1232144122249.7653×10
175QJ32-168/1432168142556.5653×16
175QJ40-24/2402425.513.6653×4
175QJ40-36/3403637.518.4653×4
175QJ40-48/4404849.222.1653×6
175QJ40-60/5406051126.1653×6
175QJ40-72/6407261330.1653×6
175QJ40-84/7408471534.7653×6
175QJ40-96/84096818.542.6653×10
175QJ40-108/94010892249.7653×10
175QJ40-120/1040120102249.7653×10
175QJ40-132/1140132112556.5653×16
175QJ50-24/2502425.513.6803×4
175QJ50-36/3503639.222.1803×4
175QJ50-48/4504841126.1803×6
175QJ50-60/5506051330.1803×6
175QJ50-84/75084718.542.6803×10
175QJ50-96/8509682249.7803×10
175QJ50-108/95010892556.5803×16

200QJ series (pump diameter 182 mm)

ModelFlow (m³/h)Head (m)StagesMotor (kW)Current (A)Outlet (mm)Cable (mm²)
200QJ20-40/320403410.1503×4
200QJ20-54/4205445.513.6503×4
200QJ20-67/5206757.518503×4
200QJ20-81/6208167.518503×4
200QJ20-93/7209379.221.7503×6
200QJ20-108/82010881125.8503×6
200QJ20-121/92012191329.8503×6
200QJ20-133/1020133101533.9503×6
200QJ20-148/1120148111533.9503×6
200QJ20-175/13201751318.541.6503×10
200QJ20-202/1520202152248.2503×16
200QJ20-243/1820243182554.5653×16
200QJ20-270/2020270203065.4653×25
200QJ20-297/2220297223065.4653×25
200QJ20-338/2520338253779.7653×25
200QJ20-350/2620350263779.7653×35
200QJ20-363/2720363273779.7653×35
200QJ20-400/3020400304596.9653×50
200QJ20-450/3420450344596.9653×50
200QJ32-26/232262410.1653×4
200QJ32-39/3323935.513.6653×4
200QJ32-52/4325247.518653×4
200QJ32-65/5326551125.8653×6
200QJ32-78/6327861125.8653×6
200QJ32-91/7329171329.8653×6
200QJ32-104/83210481533.9653×6
200QJ32-130/10321301018.541.6653×10
200QJ32-156/1232156122554.5653×16
200QJ32-195/1532195153065.4653×16
200QJ32-234/1832234183779.7653×25
200QJ32-247/1932247193779.7653×25
200QJ32-260/2032260204596.9653×25
200QJ32-286/2232286224596.9653×35
200QJ40-26/2402625.513.6653×4
200QJ40-39/3403937.518653×4
200QJ40-52/4405249.221.7653×6
200QJ40-65/5406551125.8653×6
200QJ40-78/6407861533.9653×6
200QJ40-104/840104818.541.6653×10
200QJ40-117/94011792248.2653×10
200QJ40-143/1140143112554.5653×10
200QJ40-169/1340169133065.4653×16
200QJ40-182/1440182143779.7653×16
200QJ40-208/1640208163779.7653×25
200QJ40-234/1840234184596.9653×25
200QJ40-247/1940247194596.9653×35
200QJ50-13/150131410.1803×4
200QJ50-26/2502625.513.6803×4
200QJ50-39/3503939.221.7803×4
200QJ50-52/4505241125.8803×6

Not sure which model fits? Send us the well diameter, the depth to water, the flow you need and your power supply, and we will select the pump and cable for you.

Typical Applications

  • groundwater supply
  • farm irrigation
  • town and building water supply
  • livestock water

Related Products