Pipeline Pump Installation Height and NPSH: A Worked Example

A pipeline pump is not self-priming, and it can only lift water a limited distance on its suction side. With hot water, it may need to sit below the water level. The figure that decides this is NPSHr, which our selection table lists for every build.
The simple estimate
At sea level the atmosphere can support about 10.3 m of water. Take away the pump’s NPSHr, the suction pipe losses, the vapour pressure of the liquid and a safety margin of about 0.5 m. What is left is the most the pump can sit above the water surface.
Example 1: water at 20 °C
Pump 65-160, NPSHr 2.5 m. Suction pipe losses 1.0 m. Vapour pressure of water at 20 °C is about 0.24 m. Height = 10.3 − 2.5 − 1.0 − 0.24 − 0.5 ≈ 6.0 m above the water.
Example 2: the same pump on water at 80 °C
Water at 80 °C has a vapour pressure of about 4.8 m of head. Height = 10.3 − 2.5 − 1.0 − 4.8 − 0.5 ≈ 1.5 m. The allowed lift has fallen by more than three-quarters. Much hotter, and the pump must sit below the water surface.
Other things that reduce it
- Altitude: the atmosphere supports less water the higher the site
- Long or narrow suction pipe, many bends, a partly closed valve
- Running far to the right of the duty point, where NPSHr rises
NPSHr for every build is in the selection table.
Products in This Series
Pipeline Centrifugal Pumps & CDL Multistage PumpsPipeline Pumps for HVAC Chilled and Condenser Water Circulation
Vertical inline pumps for chilled water and condenser water loops in HVAC systems: what sets the flow and head, and why closed-loop pressure matters.
Pipeline Centrifugal Pumps & CDL Multistage Pumps60 Hz and Special Voltage Pipeline Pumps and CDL Multistage Pumps
Pipeline and multistage pumps for 60 Hz and 380, 440 or 460 V supplies. Why a 50 Hz pump overloads on 60 Hz and what to send us.
Pipeline Centrifugal Pumps & CDL Multistage PumpsA, B and C Trimmed Impellers: Matching a Pipeline Pump to the Duty
The A, B and C at the end of a pipeline pump model mark trimmed impellers. How trimming lowers head and power, with the 40-250(I) family as an example.
Need a pump for your application?
Our engineers respond to technical inquiries within 24 hours.
Get a Quote