ZW100-80-20 Self-Priming Pump for Textile and Dyeing Wastewater
ZW100-80-20: 80 m³/h at 20 m on 7.5 kW, 1450 r/min, DN100/DN80. For textile, dyeing and printing wastewater.

Model: ZW100-100-15
ZW100-100-15: 100 m³/h at 15 m on 7.5 kW, 1450 r/min, DN100/DN80. With the fault table from our catalogue.
| Flow Rate | 100m³/h |
|---|---|
| Head | 15m |
| Power | 7.5kW |
| Inlet / Outlet Diameter | 100 / 80mm |
| Material | Cast iron (standard); stainless steel on request |
Not sure this pump fits your duty? Try the pump selector
ZW100-100-15 moves 100 m³/h at 15 m on a 7.5 kW four-pole motor. Large flow at low head makes it a common choice for drainage and transfer. Here is the fault table from our catalogue, which applies to every ZW pump.
| Fault | Likely cause | Remedy |
|---|---|---|
| No water | No or too little liquid in the casing; air leak on the suction pipe; low voltage; suction lift too high or suction pipe too long; heavy mechanical seal leak | Fill the casing; seal the leak; correct the voltage; lower the pump or shorten the pipe; repair or replace the seal |
| Too little water | Impeller or suction pipe blocked; impeller badly worn; speed too low | Clear the blockage; replace the impeller; restore rated speed |
| Noise or vibration | Base not firm; bearings worn; pump and motor shafts out of line | Secure the base; replace the bearings; realign |
| Hot bearings | Grease degraded or dry; bearing damaged | Replace the grease; replace the bearing |
| Leaks | Loose bolts; worn seals | Tighten; replace the seals |
Seals, bearings and impellers ship within 2 working days.
| Item | ZW100-100-15 |
|---|---|
| Flow | 100 m³/h |
| Head | 15 m |
| Motor power | 7.5 kW |
| Speed | 1450 r/min |
| Efficiency | 50 % |
| NPSHr | 4.0 m |
| Self-priming height | 5.5 m |
| Self-priming time | 3 min per 5 m |
| Suction / discharge | DN100 / DN80 |
| Weight | 300 kg |
The pump, coupling and motor are mounted on a common base. L is the overall length; L1 to L4 are base lengths; a and f locate the outlet; B1 and B2 are the base widths; H is the shaft centre height; h1 and h2 are the heights of the suction and discharge flanges; h3 is the base thickness.
| L | L1 | L2 | L3 | L4 | a | f | B1 | B2 | H | h1 | h2 | h3 | Base bolts | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZW100-100-15 | 1230 | 920 | 140 | 630 | 375 | 400 | 730 | 450 | 510 | 330 | 630 | 920 | 28 | 4ר23 |
| Flange | DN | Outer dia. D | Bolt circle | Raised face | Thickness b | Face height f | Bolts n×d |
|---|---|---|---|---|---|---|---|
| Suction | 100 | 210 | 170 | 145 | 15 | 2 | 4ר18 |
| Discharge | 80 | 190 | 150 | 125 | 15 | 2 | 4ר18 |

ZW100-80-20: 80 m³/h at 20 m on 7.5 kW, 1450 r/min, DN100/DN80. For textile, dyeing and printing wastewater.

ZW80-50-60 has the highest head in the ZW range: 50 m³/h at 60 m on 22 kW, DN80/DN65.

ZW80-80-35 comes in two builds, both 80 m³/h at 35 m on 15 kW: a compact 2900 r/min unit and a heavier 1450 r/min unit.