Two 304 Stainless IHG Pumps for Acid and Alkali at 2 MPa: An Order Explained

This order was for two vertical stainless steel chemical pipeline pumps on an acid and alkali line. The buyer’s specification was short and clear, and one line in it changed how the pumps had to be built.
| Item | Pump 1 | Pump 2 |
|---|---|---|
| Model | IHG125-200B | IHG150-400B |
| Duty | 120 m³/h at 40 m | 174 m³/h at 40 m |
| Liquid | Acid and alkali liquids | Acid and alkali liquids |
| System pressure | 0 to 2 MPa | 0 to 2 MPa |
| Wetted material | 304 stainless steel | 304 stainless steel |
The line that mattered
Our pipeline pumps are rated for a system pressure of 1.6 MPa, counted as suction pressure plus pump head. This line ran at up to 2 MPa. A pressure above 1.6 MPa has to be stated with the order so that the casing and the connections are built for it. That is the first thing we check on any IHG enquiry, and the reason we always ask for the system pressure, not just the head.
Why 304 here
The buyer specified 304 stainless steel for this plant. For liquids with chlorides or stronger chemistry we would look at 316. Either way, the chemical, its concentration and temperature decide the material and the seal.
Both models are in the pipeline pump selection table; IHG uses the same model list as ISG.
Products in This Series
Pipeline Centrifugal Pumps & CDL Multistage PumpsPipeline Pumps for HVAC Chilled and Condenser Water Circulation
Vertical inline pumps for chilled water and condenser water loops in HVAC systems: what sets the flow and head, and why closed-loop pressure matters.
Pipeline Centrifugal Pumps & CDL Multistage Pumps60 Hz and Special Voltage Pipeline Pumps and CDL Multistage Pumps
Pipeline and multistage pumps for 60 Hz and 380, 440 or 460 V supplies. Why a 50 Hz pump overloads on 60 Hz and what to send us.
Pipeline Centrifugal Pumps & CDL Multistage PumpsA, B and C Trimmed Impellers: Matching a Pipeline Pump to the Duty
The A, B and C at the end of a pipeline pump model mark trimmed impellers. How trimming lowers head and power, with the 40-250(I) family as an example.