Sewage PumpsWilden T15 Air Valve Assembly 15-2000-07 | Turbo-Flo
Wilden T15 air valve assembly 15-2000-07 for Turbo-Flo diaphragm pumps. What it does, signs of failure, and how to order the right one.

Wilden T15 shaft 15-3800-09-07 links the diaphragms in Turbo-Flo pumps. See wear signs, replacement tips, and what to confirm before ordering.
Nobody looks at the shaft until the seals start failing for no obvious reason.
The 15-3800-09-07 is the shaft on the Wilden T15, position 15 in the parts list. It joins the two diaphragms so they move together, and it runs through the center block on a pair of seals. Every stroke drags its surface across those seals, so a scratch, a pit or a patch of corrosion on it wears down new seals faster than they should go.
If you keep replacing seals, check the shaft. Light marks can sometimes be smoothed out; deep scoring can’t. And when the shaft does get changed, change the seals at the same time, otherwise a worn part just wears out the new one.
This is an original Wilden part, compatible with the matching model of genuine Wilden pump. Check the part number and position against your own parts list before ordering, and the material too if your fluid is aggressive.
Sewage PumpsWilden T15 air valve assembly 15-2000-07 for Turbo-Flo diaphragm pumps. What it does, signs of failure, and how to order the right one.
Submersible Sewage PumpsA rough service-life timeline of what actually wears out on continuous-run 300mm+ submersible sewage pumps, and which failures show warning signs versus which don’t.
Submersible Sewage PumpsDirect-on-line, star-delta, soft-start and VFD starting compared for 45-250kW submersible sewage pump motors, with the trade-offs that actually matter on site.