Pipeline Centrifugal Pumps & CDL Multistage Pumps60 Hz and Special Voltage Pipeline Pumps and CDL Multistage Pumps
Pipeline and multistage pumps for 60 Hz and 380, 440 or 460 V supplies. Why a 50 Hz pump overloads on 60 Hz and what to send us.

Model: ISG, IRG, IHG pipeline pumps
Our table gives three duty points for each pipeline pump. How flow, head, power and efficiency move together, and where on the curve to run.
Not sure this pump fits your duty? Try the pump selector
Each build in our catalogue is listed with three duty points: a low flow, the rated flow and a high flow. Together they sketch the pump curve. Take the 50-160 at 2900 r/min.
| Flow (m³/h) | Head (m) | Efficiency (%) |
|---|---|---|
| 8.8 | 33 | 45 |
| 12.5 | 32 | 52 |
| 16.3 | 30 | 51 |
Aim for the duty to sit between the low and high points listed, ideally close to the rated one. Running at a nearly closed valve heats the water in the pump; running far beyond the high point risks cavitation and overloading the motor.
Work out your system head with the head calculator, then pick the build in the selection table.
Pipeline Centrifugal Pumps & CDL Multistage PumpsPipeline and multistage pumps for 60 Hz and 380, 440 or 460 V supplies. Why a 50 Hz pump overloads on 60 Hz and what to send us.
Pipeline Centrifugal Pumps & CDL Multistage PumpsWhich vibration isolators go under a vertical pipeline pump, from SD41-0.5 pads on small frames to SD61 sets on large ones, and why they matter.
Pipeline Centrifugal Pumps & CDL Multistage PumpsWhy a pipeline pump trips its motor or runs with hot bearings: flow too high, heavy liquid, low voltage, grease and alignment. Checks in order.