La bomba de tubería funciona pero da poca o ninguna agua: causas y soluciones

| Cause | Fix |
|---|---|
| Air in the casing, pump not primed | Fill and vent again |
| Air leaking into the suction pipe or seal | Seal the joints; check the seal |
| Wrong direction of rotation | Swap two motor phases |
| Speed too low, supply voltage low | Check the supply |
| Impeller inlet or passages blocked | Open and clean |
| Foot valve blocked or leaking | Clean or repair it |
| Water level fallen, suction lift too high | Recheck the height; lower the pump |
| Wear ring and impeller worn | Replace the worn parts |
| Vortex at the inlet drawing air | Submerge the suction deeper; add a baffle |
| Discharge head higher than planned | Compare the real head with the curve |
Si la bomba da agua pero no suficiente, mida la presión de descarga y compárela con la curva en la tabla de selección. Eso le indica si el problema es la bomba o el sistema.
Productos de esta serie
Bombas centrífugas de tubería y bombas multietapa CDLBombas de tubería para circulación de agua enfriada y de condensación HVAC
Bombas verticales en línea para circuitos de agua enfriada y agua de condensación en sistemas HVAC: qué determina el flujo y la altura, y por qué es importante la presión de circuito cerrado.
Bombas centrífugas de tubería y bombas multietapa CDLBombas para tuberías de 60 Hz y tensión especial y bombas multietapa CDL
Bombas de tubería y multietapa para suministros de 60 Hz y 380, 440 o 460 V. Por qué una bomba de 50 Hz se sobrecarga en 60 Hz y qué enviarnos.
Bombas centrífugas de tubería y bombas multietapa CDLImpulsores recortados A, B y C: adaptación de una bomba de tubería al servicio
A, B y C al final de un modelo de bomba de tubería marcan impulsores recortados. Cómo el recorte reduce la altura y la potencia, con la familia 40-250(I) como ejemplo.
¿Necesita una bomba para su aplicación?
Nuestros ingenieros responden a las consultas técnicas en un plazo de 24 horas.
Obtenga una cotización